                Leading Edge Dimmer Information
 Notes For Dimmers
 Note A
  Tungsten filament GU10 lamps must be branded with a fuse base.
 Note B
   When using mains voltage halogen lamps - dimmers should be de-rated by 25%.
   Note C
 When using mains voltage halogen load transformers - maximum rating is 210VA.
 Note D
   To only be used with Touch Master Dimmers.
  Leading Edge Resistive Dimmers - Metal Plates
     Number of dimmer switches per plate
       Nominal plate size mm
    Dimmer type
   Max plate load W (Watts)
  Lamp type
 Tungsten Filament including halogen (Watts)
 Linea Halogen (Watts)
  GU10 LED (Watts)
 Min
 Max
  Max
  Min
  Max
 1
   88x88
   1x40
   400
  40
  400
   300
   10
   100
   2
 88x88
 2x40
 600
40
  300
 300
 10
 100
 3
  88x146
  3x40
  1200
 40
 400
  300
  10
  100
 4
   88x146
   4 x40
   1200
  40
  300
   250
   10
   100
   6
 150x150
 6x40
 1800
40
  300
 250
 10
 100
 8
  150x150
  8x40
  1800
 40
 300
  250
  10
  100
 9
  150x210
  9x40
  2250
 40
 250
  250
  10
  100
 12
  150x210
  12x40
  2250
 40
 200
  150
  10
  100
 12
   210x280
   12x40
   3600
  40
  300
   200
   10
   100
   16
 210x280
 16x40
 3600
40
  225
 200
 10
 100
 1
  88x88
  1x60
  600
 100
 600
  450
  15
  150
 1
   88x146
   1x1K
   1000
  150
  1000
   750
   25
   250
 Leading Edge Resistive Dimmers - Wood Plates
     Number of dimmer switches per plate
       Nominal plate size mm
    Dimmer type
   Max plate load W (Watts)
  Lamp type
 Tungsten Filament including halogen (Watts)
 Linea Halogen (Watts)
  GU10 LED (Watts)
 Min
 Max
  Max
  Min
  Max
 1
  88x88
  1x40
  400
 40
 400
  300
  10
  100
 2
   88x146
   2x40
   600
  40
  300
   300
   10
   100
   3
 88x146
 3x40
 900
40
  300
 300
 10
 100
 4
  88x146
  4 x40
  1000
 40
 250
  200
  10
  100
 6
  150x150
  6x40
  1200
 40
 200
  200
  10
  100
 9
   150x210
   9x40
   1800
  40
  200
   200
   10
   100
 Leading Edge Resistive Dimmers - Plastic Plates
     Number of dimmer switches per plate
     Nominal plate size mm
     Dimmer type
    Max plate load W (Watts)
  Lamp type
 Tungsten Filament including halogen (Watts)
 Linea Halogen (Watts)
  GU10 LED (Watts)
 Min
  Max
  Max
  Min
  Max
 1
  88x88
  1x40
   400
   40
   400
   300
   10
   100
   2
 88x88
   2x40
  600
  40
  300
  300
  10
  100
   3
88x146
  3x40
 900
 40
 300
 300
 10
 100
 4
  88x146
  4 x40
   1000
   40
   250
   250
   10
   100
 Due to constant changes in regulations, etc. users should satisfy themselves there have been no amendments.