Page 437 - Hamilton Litestat Catalogue 18/19
P. 437

                Leading Edge Inductive Push on/Off Dimmers
 Category:
200VA Inductive Dimmer
See Notes for Dimmers Page 390: Note E
300VA Inductive Dimmer
See Notes for Dimmers Page 390: Note E
 Wattage: Current Rating: Max Load:
Min Load:
200VA (low voltage) 0.8 Amp
200VA (low voltage) 25VA
1 gang 200VA 2 way 2 gang 200VA 2 way
per gang per gang
Wattage: Current Rating: Max Load:
Min Load:
300VA (low voltage) 1.25 Amp
300VA (low voltage) 50VA
Technical Insert Ref:
Description:
Technical Insert Ref:
Description:
1X2V 2X2V
1X3V
1 gang 300VA 2 way
   Grid-IT 200VA Inductive Dimmer Module
See Notes for Dimmers Page 390: Note E D2V 1 gang 200VA 2 way
 Technical Specification:
Voltage:
IP Rating:
Switched Poles: Contact Gap Minimum: Product Class 1:
Terminal Capacity:
Ambient Operating Temperature: -5° to +40°C Location: Internal Use Only Max Installation Altitude: 2000m
Standard Hamilton manufactured electrical accessories are designed to be mounted on BS4662:2006 flush wall boxes.
 220/250V AC IP2XD
Single
None
Face plate must be earthed
 200VA Terminal Capacity
200VA Earth Terminal Capacity
300VA Terminal Capacity
300VA Earth Terminal Capacity
1mm2
1.5mm2
2
2
4
2.5mm2
3
3
4mm2 Multi-Strand
1
1
6mm2
         2
          5
4
1
            2
             5
1
                  LEADING EDGE TECHNOLOGY DIMMERS for use with low voltage toroidal transformers and some LED lamps.
Fixing Centres: 200VA Inductive Dimmer 300VA Inductive Dimmer Grid-IT Inductive Dimmer Module
60.3mm
inductive load.
More information can found on our website. visit www.hamilton-litestat.com
      1X2V 2X2V 1X3V D2V
Note: It is recommended to contact the manufacturer of the transformer to confirm that it is dimmable and is considered to be an
Due to constant changes in regulations, etc. users should satisfy themselves there have been no amendments.