Page 460 - Hamilton 2020-2021
P. 460

                Trailing Edge Push on/off Dimmers
 Category:
Trailing Edge Dimmer
See Notes for Dimmers Page 441: Note A,B, C, E
Grid-IT Trailing Edge Dimmer Module
See Notes for Dimmers Page 441: Note A,B, C, E
  Technical Insert Ref:
Description:
Technical Insert Ref:
Description:
1XTE 2XTE 3XTE 4XTE W2XTE
1 gang 250W/210VA Multi-Way 2 gang 250W/210VA Multi-Way 3 gang 250W/210VA Multi-Way 4 gang 250W/210VA Multi-Way 2 gang 250W/210VA Multi-Way max 200W per gang
Dimmer Dimmer Dimmer Dimmer Dimmer
Dimmer
DTE
1 gang 250W/210VA Multi-Way Dimmer Module
     W4XTE
4 gang 250W/210VA Multi-Way max 200W per gang
  Technical Specification:
Wattage:
Current Rating: Max Load:
Minimum Load:
Voltage:
IP Rating:
Switched Poles:
Contact Gap Minimum:
Product Class 1:
Ambient Operating Temperature: Location:
 Max Installation Altitude:
Single
None
Face plate must be earthed -5° to +40°C
Internal Use Only
2000m
Terminal Capacity:
250W Resistive 210VA Inductive 1.1 Amp per gang 250W Resistive 210VA Inductive 25W/25VA 220/250V AC IP2XD
Standard Hamilton manufactured electrical accessories are designed to be mounted on BS4662:2006 flush wall boxes.
Standards:
BS EN ISO Standard:
BS EN 60669-2-1
      6mm2
        Terminal Capacity
1mm2
    2
TRAILING EDGE TECHNOLOGY DIMMERS. Are suitable for control of both resistive and inductive loads. When used for dimming low voltage electronic halogen transformers it must be noted that the dimmer controls the primary side of the transformer.
Trailing Edge Dimmer
2XTE W2XTE
2
      Earth Terminal Capacity
       5
4
Grid-It Trailing Edge Dimmer Modules
Fits one Grid-IT aperture
DTE
Note: For multi-way switching a push to make retractive switch should be installed in the other positions. (Note: standard two way switches will not work with this product).
Fixing Centres:
60.3mm
120.6mm
1XTE
3XTE
3
1
1
              Due to constant changes in regulations, etc. users should satisfy themselves there have been no amendments. E&OE.
4XTE W4XTE
1.5mm2
2.5mm2
4mm2 Multi-Strand
   460
www.hamilton-litestat.com
TECHNICAL SPECIFCATIONS